Clearance Dimensions (Proximity To Cabinets); Clearance Dimensions (Wood/Composite Overlay) - Viking F20513A Installation Manual

Professional freestanding 30”gas and gas self-clean sealed burner range
Table of Contents

Advertisement

Clearance Dimensions
• This range may be installed directly
• Wall cabinets above the range must be a
adjacent to existing 36" (91.4 cm) high
base cabinets.
IMPORTANT: The side trim MUST be
3/8" (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.
• The range CANNOT be installed
directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above 36"
(91.4 cm) high. There must be a
minimum of 6" (15.2 cm) side
clearance from the range to such
combustible surfaces above the
36" (91.4 cm) counter height.
• Within the 6" (15.2 cm) side
clearance to combustible vertical
surfaces above 36" (91.4 cm), the
maximum wall cabinet depth
must be 13" (33.0 cm) and wall
"
3 6
)
c m
cabinets within this 6" (15.2 cm)
. 4
9 1
(
side clearance must be 18"
(45.7 cm) above the 36"
(91.4 cm) high countertop.
CAUTION
Burn hazard
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
Note: Minimum clearance for back wall is 0" with
become hot and cause burns. If a cabinet
backguard or high-shelf.
storage is to be provided the risk can be
reduced by installing a rangehood that
Note: If a range hood is installed, wall cabinets
projects horizontally a minimum 5"
above the range have a different minimum
(12.7 cm) beyond the bottom of cabinets.
clearance height.
8
(Proximity to Cabinets)
minimum of 42" (106.7 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
2 9
- 7 /
( 7 5
8 "
. 9
c m
.
a x
)
" m
)
c m
1 3
. 0
3 3
(
i n .
" m
)
c m
4 2
6 "
6 . 7
( 1 0
m i
( 1 5
n .
. 2
c m
)
i n .
" m
)
1 8
c m
. 7
( 4 5
"
3 / 8
)
c m
9 5
( 0 .
Clearance Dimensions
The bottom of a standard hood should be
W o
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66" (167.6 cm) to 72" (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information.
These dimensions provide for safe and
efficient operation of the hood.
6 6
" m
( 1 6
i n .
7 . 6
c m
t o
7 2
" m
( 1 8
a x
2 . 9
c m
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
Wall Installation
"
3 0
)
c m
3 0
6 6
. 2
" m
" m
( 7 6
( 7 6
( 1 6
i n .
i n .
. 2
7 . 6
c m
c m
t o
)
t o
3 6
7 2
)
6 "
m )
" m
" m
. 2 c
( 9 1
( 1 8
a x
a x
( 1 5
. 4
.
2 . 9
.
c m
c m
)
)
Island Installation
9
(Wood/Composite Overlay)
o d
/ C o
m p
O v
o s i
e r l
t e
a y
"
2 4
)
c m
. 0
( 6 1
o r
"
2 7
)
c m
. 6
3 0
)
( 3 8
" m
0 "
( 7 6
i n .
m )
. 2
.
0 c
c m
(
t o
)
3 6
)
" m
( 9 1
a x
. 4
.
c m
)
Note: Minimum clearance for back wall
is 0" with backguard or high-shelf. See
Standoff Bracket Removal section to
allow 0" clearance.
Note: 6" (15.2 cm) min. with island trim and
combustible rear wall. 0" with island trim and
non-combustible rear wall. See Standoff
Bracket Removal section to allow 0" clearance.

Advertisement

Table of Contents
loading

This manual is also suitable for:

F20513Vgcc530-4bVgsc530-4b

Table of Contents