Note. Clearance is not required at the top and bottom of
the chassis.

Rack-Mounting

Refer to the important guidelines below before installing the
OmniSwitch chassis in a rack.
Rack-mounting the chassis requires three people—two
people to hold the chassis and position it in the rack and a
third person to secure the chassis to the rack by using the
attachment screws.
The chassis has two integral rack-mount flanges that
support standard 19" rack mount installations. Refer to
page 11
for information on optional rack-mounting hard-
ware.
Alcatel-Lucent does not provide rack-mount screws.
Use the screws supplied by the rack vendor.
To prevent a rack from becoming top heavy, it is recom-
mended that you install the switch at the bottom of the rack
whenever possible.
If you are installing the switch in a relay rack, be sure to
install and secure the rack per the rack manufacturer's
specifications.
Refer to
page 7
for important chassis airflow recom-
mendations before installing.
8
Installing the Hardware
To rack-mount the switch, follow the steps below:
1
Mark the holes on the rack where the chassis is to be
installed.
2
Using two people, lift and position the chassis until the
rack-mount flanges are flush with the rack post.
3
Align the holes in the flanges with the rack holes you
marked in step 1.
4
Once the holes are aligned, use a third person to insert
a screw through the bottom hole on each flange. Tighten
both screws until they are secure.
O m
n iS
w it
c h
9 7 0
0
A
CM
M
1
NI
2
3
4
B
PW
R
PS 1
PS 2
PS 3
5
6
NI
7
8
May 2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch os9800Omniswitch os9700Omniswitch os9600

Table of Contents