Goodman CONDENSING UNIT HEAT PUMP Installation & Service Reference page 13

Condensing unit heat pump
Table of Contents

Advertisement

Submenu Item
Mode (MODE)
CFM (CFM)
Submenu Item
Heat Airflow Trim
(HT TRM)
Heat ON Delay
(HT ON)
Heat OFF Delay
(HT OFF)
Defrost Interval
(DEFROST)
Compressor Delay
(CMP DLY)
T
M
HERMOSTAT
ENU
If this heat pump is installed with a CT compatible furnace, the system is recognized as a dual fuel system. The balance point
temperature should be set via the thermostat advanced menu. Navigate to the THERMOSTAT menu. Press the INSTALLER
CONFIG key. Navigate to the SETUP menu and press the INSTALLER CONFIG button. Navigate to dF BAL PNT. Adjust the
dual fuel system balance point using the back/forward arrows.
A
C
/H
P
IR
ONDITIONER
EAT
Displays the current air conditioner operating mode
Displays the airflow for the current operating mode
User Modifiable Options
-10% to +10% in 2% increments,
default is 0%
5, 10, or 15 seconds, default is 5
seconds
30, 50, 70, or 90 seconds, default
is 30 seconds
30, 60, 90, or 120 minutes, default
is 30 minutes.
0, 5, 15, or 30 seconds, default is 5
seconds
A
F
UMP
DVANCED
EATURES
STATUS
Indication (for Display Only; not User Modifiable)
HEAT SET-UP
Selects the airflow trim amount; applies to
heat pump only.
Selects the indoor blower heat ON delay;
applies to heat pump only.
Selects the indoor blower heat OFF delay;
applies to heat pump only.
Selects the time interval between defrosts;
applies to heat pump only.
Selects the compressor off time after a
reversing valve shift; applies to heat pump
only.
13
M
(
'
)
ENUS
CONT
D
Comments