User Security Codes

The system supports up to 16 security codes, which can each be assigned one of 4 authority levels. The
authority level determines the functions each code can perform as follows:
Authority Levels
(authority levels can be assigned to users 3-16 only; users 1 and 2 cannot be changed)
Level
User No.
Installer
01
System
02
Master
0-User
03-16
1-Arm Only
see "user"
2-Guest
see "user"
3-Duress
see "user"
Refer to the user guide for procedures on adding/deleting security codes and changing attributes.
The following is a brief description of how to add user codes.
Changing the System Master code...
Using Installer code: Installer code + [8] + 02 + new code
Using current System Master code: System Master code + [8] + 02 + new code + new code again
Adding a User Code:
Deleting a User Code: Master code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes: Master code + [8] + 2-digit user no. + [#] [attribute no.] + value
Attributes:
1 =
Authority Level 0-3 (see Authority Level table above)
2 =
Access Group 0-8 (0 = not assigned to a group)
3 =
Not Used
4 =
RF Zone No.;assigns user number to button type zone (keyfob) for arm/disarm.
(keyfob must be enrolled in system first; see Wireless Key Templates section)
5 =
Open/Close Paging; 1 for yes, 0 for no
Summary Of Arming Modes
Arming Mode
Exit Delay
AWAY
Yes
STAY
Yes
NIGHT-STAY
Yes
INSTANT
Yes
MAXIMUM
Yes
Panic Keys
There are three Panic keys (A, B, and C) that, if programmed, can be used to manually initiate alarms and
send a report to the central station by pressing and holding the appropriate key for at least 2 seconds. Each
key can be programmed for 24-hour Silent, 24-hour Audible, Fire, or Personal Emergency responses.
Keys
Displayed as Zone
[A] (∗/1)
[B] (∗/#)
[C] (3/#)
Functions
(default=4112) perform all security functions except can disarm only if used to arm; can
enter program mode; can change System Master code; cannot assign any other user codes
(default 1234) only one system master code per system; can perform all
security functions, add/delete users, change system master code, view event log, set system
clock, program keypad macro, program scheduled events, activate output devices
(triggers/relays)
perform security functions (arm, disarm, etc.) only; cannot add/delete
users, view event log, set system clock or program scheduled events
arm system only
can disarm the system only if it was used to arm the system
performs security functions, but also silently sends a duress message to the central station;
reports as duress code user number.
Master code + [8] + 2-digit user no. + user's code
Values
Features for Each Arming Mode
Entry Delay
Perimeter Armed
Yes
Yes
Yes
No
No
IMPORTANT: For a Silent panic function (if programmed) to be of
95
practical value, you must program a report code for the zone and the
99
system must be connected to a central station.
96
Interior Armed
Yes
Yes
Yes
No
Yes
only those zones listed in
Night-Stay zone list
Yes
No
Yes
Yes
2-15