IBM 2200VA LCD 2U User Manual page 4

Lcd 2u rack uninterruptible power supply for ibm system x
Table of Contents

Advertisement

Features
The IBM 2200VA LCD 2U Rack UPS includes the following features and capabilities:
It has a high efficiency 2.2 KVA UPS for increased rack power density.
It occupies only 2U of vertical rack space.
It has over 95% energy efficiency at 100% load.
It has an LCD display that provides intuitive, at-the-rack management and monitoring capabilities that
supports nine languages:
English.
French.
German.
Spanish.
Russian.
Korean.
Japanese.
Simplified Chinese.
Traditional Chinese.
It has 10 receptacles:
Model 5395-2AX (100V/120V) has six NEMA 5-20R, two IEC 320 C19, and two IEC 320 C13.
Model 5395-2KX (230V) has two IEC 320 C19 and eight IEC 320 C13.
Its bundled intelligent IBM UPS Manager software enhances control and manageability
It has IPv6 compliance for future proofing IP addressing and security.
It has a real-time clock that enables precise shutdown and power up of systems in preferred
sequence and time stamping on event logs to track and record specific power-related occurrences.
It integrates with IBM Systems Director Active Energy Manager for power and thermal trending
analysis and management.
Its load segments allow for individual control of receptacle groups, maximizing run time for critical
devices.
It has an optional network management card (part number 46M4140) for enhanced UPS monitoring
and control.
It allows dual channel communication through the USB port and optional Network Management Card
at the same time, which is an effective redundancy feature that maximizes communications flexibility.
It has an optional Extended Battery Module (EBM) for increased runtime requirements.
It has a Remote Emergency Power Off (REPO) port to remotely power off the UPS unit to prevent
battery operation during a power failure.
It requires a 20A (110V/120V model) or 10A (230V model) single-phase circuit.
It has hot swap batteries for maximum uptime, availability, and ease of maintenance.
It has an optional Environmental Monitoring Probe (part number 46M4113) for thermal management
requirements (temperature and humidity), which requires that the Network Management Card be
installed.
Its Advanced Battery Management (ABM) three-stage charging technology significantly extends
battery service life and optimizes recharge time. The three stages are:
1.
The battery is quickly charged to 90% to make sure the UPS is prepared for the next outage.
2.
ABM finishes charging the battery with a more moderate float charge.
3.
Once the battery is charged, ABM turns the charger off, preventing the batteries from being
overcharged.
IBM 2200VA LCD 2U Rack Uninterruptible Power Supply for IBM System x
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2200va

Table of Contents