Lenovo ThinkCentre Hardware Maintenance Manual page 65

Machine types: 1729, 1731, 1732, 1734, 1736, 1737, 7074, 7075, 7077, 7078, 7556, and 7559
Hide thumbs Also See for ThinkCentre:
Table of Contents

Advertisement

Diagnostic Error Code
000-197-XXX BIOS test warning
000-198-XXX BIOS test aborted
000-199-XXX BIOS test failed, cause unknown
000-250-XXX BIOS APM failure
000-270-XXX BIOS ACPI failure
001-000-XXX System Test Passed
001-00X-XXX System Error
001-01X-XXX System Error
001-024-XXX System Addressing test failure
001-025-XXX System Checksum Value error
001-026-XXX System FLASH data error
001-027-XXX System Configuration/Setup error
001-032-XXX System Device Controller failure
001-034-XXX System Device Buffer Allocation failure
001-035-XXX System Device Reset condition detected
001-036-XXX System Register error
FRU/Action
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 53.
2. Re-run test.
3. Replace the component that is called out in warning
statement
4. Replace the component under test.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 53.
2. Flash the system and retest. See "Flash update
procedures" on page 185.
3. Go to "Undetermined problems" on page 78.
1. Go to "Undetermined problems" on page 78.
2. Flash the system and re-test.
3. Replace component under function test.
1. Flash the system. See "Flash update procedures"
on page 185.
2. System board
1. Flash the system. See "Flash update procedures"
on page 185.
2. System board
No action
System board
System board
System board
1. Flash the system. See "Flash update procedures"
on page 185.
2. System board
1. Flash the system. See "Flash update procedures"
on page 185.
2. System board
1. Run the Setup Utility program.
2. Flash the system. See "Flash update procedures"
on page 185.
3. System board
System board
1. Reboot the system.
2. Flash the system. See "Flash update procedures"
on page 185.
3. Run memory test.
4. System board
System board
System board
Chapter 7
.
Symptom-to-FRU Index
59