Mitsubishi HS-HD1100U Service Manual page 13

Hide thumbs Also See for HS-HD1100U:
Table of Contents

Advertisement

4. PCB-1394/D-VHS
1. Remove the Top Cover.
(Refer to Para. 1 of the DISASSEMBLY.)
2. Lift and remove the Cover D VHS as shown in Fig.10.
3. Remove the one screw (a) and remove the PCB
HOLDER shown in fig. 10.
4. Disconnect the connectors EE ,EK and EX on the PCB-
1394/D-VHS .
5. Pull out the Part A,lift and remove the Spring Earth
EMC as shown in Fig. 10.
6. Unfasten the one screws (b) shown in Fig. 10 and
remove the ASSY PCB-1394/D-VHS.
7. Separate the bottom of the Shield Cover from the ASSY
PCB-1394/D-VHS first. Remove the Shield Cover
moving the bottom in the direction shown by the arrow
(A) as shown in Fig. 10.
8. Disconnect thirteen soldering connections and remove
the PCB-1394/D-VHS as shown in Fig. 11.
PCB HOLDER
a
PCB-1394/D-VHS
Soldered part
- 9 -
Cover D VHS
Part A
b
Spring Earth EMC
ASSY PCB-1394/D-VHS
Shield Cover
A
Fig. 10
Soldered part
Soldered part
Soldered part
Soldered part
Fig. 11