Self Propel Feature; Agitator Belt - Hoover R3 7-96 Owner's Manual

Self-propelled upright cleaners
Table of Contents

Advertisement

The headlight
What to buy
This cleaner uses a 12 volt, wedge base bulb.
Hoover part No. 27313101
How to replace
Disconnect cleaner from
electrical outlet.
1. Place screwdriver into one of
the slots at lower edge of lens.
Press handle of screwdriver
down to release lens. Repeat
in second slot if necessary.
2. Lift out lens.
3. Pull old bulb straight out of
socket. Push new bulb straight
into socket until locked in place.
Excessive force is not re-
quired.
4. Replace lens by inserting
tabs on top of lens under edge
of opening on cleaner.
5. Press firmly at bottom of lens
to snap lens into place.
17
SELF
PROPEL
BELT
AGITATOR
BELT
What to buy
Agitator belt - Hoover part No. 38528008
Self Propel belt - Hoover part No. 160147

Agitator belt

When to replace
Check from time to time to be sure the belt is in good condition. If it
is stretched, cut, or broken, it should be replaced.
NOT BROKEN
BROKEN
The cleaner must be turned on for the indicator to register a
broken belt.
The "BELT CHECK" indicator does not register a broken Self Propel
belt.
The belts
There are two belts on your
cleaner. One belt drives the
agitator; the other operates the

Self Propel feature.

When buying new belts, you
should always insist on genuine
HOOVER parts. Other belts
may not meet the Hoover
design and quality control
standards. They may not
operate the agitator or Self
Propel transmission correctly
and may cause damage.
The "BELT CHECK" indicator
(some models only) will spin
when the cleaner is turned on
and the agitator belt is not
broken.
If the indicator does not spin
and the orange bar is visible
when the cleaner is turned on,
the belt is broken and must
be replaced.
Continued
18

Hide quick links: