Carrier 38TXA Product Data page 14

With puron (r-410a) 60 hz sizes 024 thru 060
Hide thumbs Also See for 38TXA:
Table of Contents

Advertisement

Combination ratings continued
UNIT
SIZE-SERIES
CC5A/CD5AW060
CD5AA048
CE3AA048
CE3AA060
048-30
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BW048
CJ5A/CK5A/CK5BX060
CK3BA048
CK3BA060
CJ5A/CK5A/CK5BX060*
CJ5A/CK5A/CK5BA060
CK3BA060
F(A,B)4AN(F,B,C)060
FG3AAA060
FK4CNB006+Puron® (R-410A) TXV**
FK4CNB006+96 Piston††
FV4ANB006
FX4ANB060
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BX060
CK3BA060
060-31
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BX060
CK3BA060
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BX060
CK3BA060
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BX060
CK3BA060
* Tested combination
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in perfor-
mance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Carrier furnaces are equipped with
TDR except for the 58GFA.
‡ Based on computer simulation. TXV must be Puron® compatible and hard shutoff type.
** Ratings shown are with FK4C R-22 TXV replaced with Puron® TXV.
†† Ratings shown are with FK4C R-22 TXV replaced with Piston Body Kit and piston shipped with outdoor unit.
EER
— Energy Efficiency Ratio
LLS
— Liquid-Line Solenoid
SEER — Seasonal Energy Efficiency Ratio
TDR
— Time-Delay Relay
TXV
— Thermostatic Expansion Valve
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for
other combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
14
INDOOR
TOT. CAP.
UNIT
BTUH
47,000
46,000
46,500
47,000
46,500
46,000
47,500
46,000
46,500
59,000
58,000
58,000
58,000
57,000
59,000
59,000
58,000
58,000
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
57,000
58,000
57,000
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
57,000
58,000
57,000
COILS + 58U(H,X)V100-20 VARIABLE SPEED FURNACE
57,500
58,500
57,500
COILS + 58U(H,X)V120-20 VARIABLE SPEED FURNACE
57,500
58,500
57,500
FACTORY-
SUPPLIED
ENHANCE-
Standard
MENT
Rating
TDR
14.00
TDR
13.50
TDR
13.50
TDR
14.00
TDR
13.50
TDR
13.50
TDR
14.00
TDR
13.50
TDR
13.50
LLS
LLS
LLS
LLS & TDR
12.20
LLS
LLS & TDR
13.25
LLS & TDR
13.25
LLS, TDR, & TXV
13.25
LLS, TDR, & TXV
12.50
LLS & TDR
12.50
LLS & TDR
13.00
LLS & TDR
12.50
LLS & TDR
12.75
LLS & TDR
13.00
LLS & TDR
12.75
LLS & TDR
13.00
LLS & TDR
13.25
LLS & TDR
13.00
LLS & TDR
12.75
LLS & TDR
13.00
LLS & TDR
12.75
SEER
Carrier Gas Furnace
or Accessory
Accessory
TDR†
TXV‡
14.00
13.50
13.50
14.00
13.50
13.50
14.00
13.50
13.50
13.00
12.50
12.50
12.20
EER
12.50
12.15
12.20
12.50
12.45
12.25
12.75
12.25
12.45
11.10
10.95
10.95
10.60
10.80
11.55
11.55
11.55
10.95
11.00
11.25
11.00
11.05
11.30
11.05
11.20
11.50
11.20
11.05
11.35
11.05

Hide quick links: