Piping Diagrams

Model : M18YJ
Indoor Unit
Th2
Th1
Heat
Exchanger
(Evaporator)
LOC.
Th1
Thermistor for suction air temperature
Th2
Thermistor for evaporator inlet temperature
Th3
Thermistor for evaporator outlet temperature
Th4
Thermistor for evaporator middle temperature
Th5
Thermistor for discharge pipe temperature
Th6
Thermistor for condensing temperature
※ EEV : Electronic Expansion Valve
Th7
Thermistor for outdoor air temperature
Liquid Side
2-Way Valve
Th4
Th3
Gas Side
Accumulator
3-Way Valve
Description
Outdoor Unit
EEV
Compressor
- 3 -
Heat
Exchanger
(Condenser)
Th6
Reversing Valve
Th5
Cooling
Heating
PCB Connector
CN-TH1(Indoor)
CN-TH2(Indoor)
CN-TH3(Indoor)
CN-TH2(OUTDOOR)
CN-TH1(OUTDOOR)
Th7