Piping Diagrams - Friedrich M18YJ Manual

Hide thumbs Also See for M18YJ:
Table of Contents

Advertisement

Piping Diagrams

Model : M18YJ
Indoor Unit
Th2
Th1
Heat
Exchanger
(Evaporator)
LOC.
Th1
Thermistor for suction air temperature
Th2
Thermistor for evaporator inlet temperature
Th3
Thermistor for evaporator outlet temperature
Th4
Thermistor for evaporator middle temperature
Th5
Thermistor for discharge pipe temperature
Th6
Thermistor for condensing temperature
※ EEV : Electronic Expansion Valve
Th7
Thermistor for outdoor air temperature
Liquid Side
2-Way Valve
Th4
Th3
Gas Side
3-Way Valve
Description
Outdoor Unit
Accumulator
Compressor
- 3 -
EEV
Heat
Exchanger
(Condenser)
Reversing Valve
Th5
PCB Connector
CN-TH1(Indoor)
CN-TH2(Indoor)
CN-TH3(Indoor)
CN-TH2(OUTDOOR)
CN-TH1(OUTDOOR)
Th7
Th6
Cooling
Heating

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M18cjM24cj

Table of Contents