VISIONPRO
IAQ TOTAL HOME COMFORT SYSTEM
ISU
Parameter
Installer Setup
Number
Name
190
Reversing Valve
O/B
200
Back-up Heat
Source Applies to
both Aux and
EmHeat
210
External Fossil
Fuel Kit
220
CPH for 1st
Stage Cool/
Compressor
230
CPH for 2nd
Stage Cool/
Compressor
240
CPH for 1st
Stage
Conventional
Heat or Auxiliary
250
CPH for 2nd
Stage
Conventional
Heat or 2nd
Stage Auxiliary
260
CPH for 3rd
Stage Heat
270
CPH for
Emergency Heat
280
Continuous
USU
Backlight
300
Changeover
310
Deadband
320
Temperature
USU
Indication Scale
330
Daylight Saving
USU
68-0287—04
Table 3. Installer Setup Menu. (Continued)
Settings
(Factory Defaults Shown in Bold)
0
Changeover valve—O/B terminal is
energized in cooling
1
Changeover valve—O/B terminal is energized
in heating
E
Auto Discover
0
Electric backup heat
1
Fossil fuel backup heat
1
External Fossil Fuel kit controls backup
0
heat*
Thermostat controls backup heat
1-6
3—cph recommended for compressors
1, 2, 4, 5, 6—other cycle rate settings
E
Auto Discover
1-6
3—cph recommended for compressors
1, 2, 4, 5, 6—other cycle rate settings
E
Auto Discover
1-12
1—1 cph used for steam and gravity
3—3 cph used for hot water system and high
efficiency (90% or better) furnaces
5—5 cph used for standard fossil fuel forced
air (less than 80% efficient) systems
9—9 cph used for electric furnaces
2, 4, 6, 7, 8, 10, 11, 12—other cycle rate
settings
E
Auto Discover
1-12
1—1 cph used for steam and gravity
3—3 cph for hot water systems and high
efficiency (90% or better) furnaces
5—5 cph for standard fossil fuel forced air (less
than 90% efficient) systems
9—9 cph used for electric furnaces or electric
auxiliary heat for heat pump systems
2, 4, 6, 7, 8, 10, 11, 12—other cycle rate
settings
E
Auto Discover
1-12
1—1 cph used for steam and gravity
3—3 cph for hot water systems and high
efficiency (90% or better) furnaces
5—5 cph for standard fossil fuel forced air (less
than 90% efficient) systems
9—9 cph used for electric furnaces or electric
auxiliary heat for heat pump systems
2, 4, 6, 7, 8, 10, 11, 12—other cycle rate
settings
E
Auto Discover
9
Default
1-12
Only shown if heat pump is selected.
0
Backlight not on continuously. Thermostat
backlight comes on with each key press.
1
Backlight is on continuously.
0
Manual
1
Auto
3
2.0
3°F
2.0°C
2
1.5
2°F
1.5°C
4
2.5
4°F
2.5°C
5
3.0
5°F
3.0°C
6
3.5
6°F
3.5°C
7
4.0
7°F
4.0°C
8
4.5
8°F
4.5°C
9
5.0
9°F
5.0°C
Note: degrees C is not same as degrees F
0
Fahrenheit temperature display
1
Celsius temperature display
2
Enabled (US 2007)
0
Disabled
1
Enabled (US 1987)
Only shown if ISU172 = 2.
Only shown if ISU172 = 2 and ISU176 = 1 or
greater.
*Cannot control dual fuel when used with W8835
Envirazone Panel.
Only shown if ISU172 = 2 and ISU200 = 1.
Only shown if ISU174 = 2.
Only shown if ISU172 = 2 and ISU176 = 1 or higher.
Default varies based on types of heating.
Only shown if ISU176 = 2 or for Heat Pump systems
with 2 stages of Auxiliary Heat.
Default varies based on types of heating.
Only shown if ISU176 = 3.
Default varies based on types of heating.
If backlight is on continuously, it is low-intensity.
Light changes to full brightness after pressing any
key.
Auto Changeover allows user to choose heat, cool,
off or auto. When set to Auto the thermostat will
automatically choose heat or cool based on room
temperature and heat/cool set points. Manual
changeover allows the user to manually toggle
between heat, cool and off.
Only shown if ISU300 = 0. The deadband indicates
the minimum number of degrees that are allowed
between the heat and cool settings when in auto
changeover. For example, if the deadband is set to
3°F and the cool setpoint is 75°F the warmest heat
setpoint allowed would be 72°F.
Set to 0 in areas that do not follow daylight savings
time.
14