3. Check that Power Good signal is at "high" logic, normal
operation.
4. Check that HERCULES is not in standby mode. Pin 15 of
HERCULES should be 0 V_dc.
5. Make sure H-drive pulse is there. This can be checked at
resistor R3239. If H-drive does not exist, remove resistor
R3239 to check if there is loading.
Note: When the set shuts down after a few second after power
"ON", the main cause is that Vg2 not aligned properly, try
adjusting Vg2 during the few seconds of power "ON".
5.8.7
Video Processing
No Picture
When "no picture in RF", first check if the microprocessor is
functioning o.k. in section "Controller". If that is o.k., follow the
next steps.
When "no picture in AV", first check if the video source
selection is functioning o.k. in section "Source Selection". If that
is o.k., follow the next steps.
1. Check that normal operating conditions are met.
2. Check that there is video signal at pin 81. If no video,
demodulator part of the HERCULES is faulty, replace with
new HERCULES.
3. If video signal is available at pin 81, check pin 56, 57, and
58 for the RGB signal.
4. If signal is not available, try checking the BRIGHTNESS
and/or CONTRAST control, and make sure it is not at zero.
5. If still with the correct settings and no video is available,
proceed to the CRT/RGB amplifier diagram.
For sets with TDA9178, follow steps below:
1. Put Option Byte 2 bit 4 to "0"; if video signal is not available,
then check fault finding section "Controller", Section
"Source Selection", and steps above.
2. If video is available but not correct, put Option Byte 2 bit 4
to "1", then check if LTI panel is present. If not, put LTI
panel in the main chassis (connector 1221).
3. If LTI panel is in main chassis, check cable between LTI
panel and main chassis (position is 1206). If it is
connected, then the LTI panel is faulty, replace it.
For sets with Scavem, and Scavem does not work, follow steps
below:
1. Check Scavem coil connector (position is 1361) if
connected; if not, connect it.
2. If connected, check NVM "bit storage" byte 1 bit 7; if it is not
"1", set it to "1".
3. If it is "1", then check the data of the NVM addresses as in
the next table. If the data is not correct, then set these
addresses to diagram values.
4. If it still not works, track Scavem output from pin 64 of
HERCULES to CRT panel.
Table 5-5 NVM default values for Scavem
Description
SPR, WS
VMA, SVM
NVM_SOC_SMD
Service Modes, Error Codes, and Fault Finding
Address
Address
(dec)
(hex)
Value (hex)
140
8C
00
141
8D
32
142
8E
03
L04E AE
5.8.8
Audio Processing
No Sound
Picture Ok,
No Sound
Tuner IF Ok
Not Ok
Ok
Check AUDOUTLSL &
AUDOUTLSR pin at
Not Ok
UOCIII
Ok
Check Audio
Not Ok
Amplifier
Figure 5-13 Fault finding tree "No sound"
No RF audio for QSS/Inter-Carrier stereo sets.
1. Check pin 99 and 100 for SIF signal (for QSS) or pin 104
and 105 for video with SIF (for Inter-Carrier)
2. If signal is not present, check for the QSS/FMI bit settings.
Check also the NVM data.
3. If signals are present and still no audio, check the audio
supply voltage +8V are present.
4. If still no audio signal at Hercules output, Hercules is faulty.
No AV audio.
1. Check troubleshooting methods in section "Source
Selection".
2. Check the output of the Hercules to see if there is signal
available. If no, check the normal operating condition and
also the NVM data.
3. If still no audio signal at Hercules output, Hercules is faulty.
Note: If there is audio signal at Hercules output and no audio
at loudspeaker, proceed to Audio Amplifier troubleshooting
methods.
5.8.9
Audio Amplifier
No RF nor AV audio at the loudspeaker:
1. Check that the normal operation condition of the amplifier
is met.
2. If normal operation conditions are met, check the continuity
from Hercules output to input of the amplifier.
3. If continuity is there and still no audio, check speaker wire
connections. If still no audio, amplifier IC might be faulty.
5.
EN 19
Check Tuner/IF
Check UOCIII IC
Check Audio
Check Power
Power Supply
Supply
Ok
Check Audio
Replace Audio
Amplifier Circuit
Not Ok
Amplifier
and loud speaker
Ok
Check NVM
E_14480_065.eps
201005

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L04e ae

Table of Contents