(Table 2.) Diode Tester Measure Value of P102A and P103A's Each Terminal
+ : red, - : black
Terminal Shape :(Top view, components side)
1 2 3 4 5 6 7 8 9 1011
DIODE TESTER
-
GND
DIODE TESTER
-
GND
P103A
MEASURE
+
1
Over 1.2V
2
OPEN
3
OPEN
4
OPEN
5
OPEN
6
OPEN
7
OPEN
8
Over 1.9V
9
OPEN
MEASURE
+
2
Over 1.9V
3
Over 1.9V
4
Over 1.9V
5
Over 1.9V
1 2 3 4 5 6 7
GND
P103A
DIODE TESTER
+
GND
P102A
DIODE TESTER
+
GND
-67-
P102A
MEASURE
-
1
Over 0.4V
2
Over 0.8V
3
Over 0.8V
4
Over 0.8V
5
Over 0.8V
6
Over 0.8V
7
Over 0.8V
8
Over 0.8V
9
Over 0.8V
MEASURE
-
2
Over 0.8V
3
Over 0.8V
4
Over 0.8V
5
Over 0.8V