1) Vsus (173V) Voltage CHECK: When keeping above 10 volt, Using not less than 1 K ohm 5
Watt resistance to discharge remaining voltage.(Under 5 volt )
2) Vadd (68V) Voltage CHECK: When keeping above 10 volt, Using not less than 1 K ohm 5
Watt resistance to discharge remaining voltage.(Under 5 volt )
7. Check the Connectors Connection.
8. If no fault detected from above tests, do the following.
(1) Use DIODE TESTER reffering to the following Table.1~4.
(2) If abnormal components CHECK, then replace Y-SUS PCB.
(3) If NORMAL, Check the Connectors' Connection again.
(Table 1.) Diode Tester Measure Value of P101A's Each Terminal
+ : red, - : black
NAME
DIODE TESTER
1
170V
GND
2
163V
GND
3
15V
GND
MEASURE
+
After about 10
-
sec, Open
+
After about 10
-
sec, Open
+
Over 0.5V
-
-66-
DIODE TESTER
-
+
-
+
-
+
MEASURE
Over 0.7V
Open
Over 0.4V