I/O EMI Shield
The I/O EMI shield (LP340/LP350: 330-0604-xx; LP340B: 330-0461-xx) covers the connectors on the
side of the projector.
1
Remove the bottom case (see page 17).
2
Remove the two Phillips screws on either side of the CableWizard connector.
3
Remove the two jack screws on either side of the M-1 connector.
4
Gently work the shield off of the connectors.
Assembly Notes
Make sure the small fingers in the holes that fit over the S-Video and composite video connectors fit
snuggly.
Make sure the fingers on the bottom of the shield contact the chassis. Contact assures that video and
audio noise drain off to ground.
Torque the two screws and two jack nuts to 4 in.-lbs. (.452 N m).
LP340/340B/350 Service Manual
39