Honeywell T7200D Product Data page 8

Series 2000 programmable commercial thermostats and subbases
Hide thumbs Also See for T7200D:
Table of Contents

Advertisement

T7200D,E, T7300D,E,F AND Q7300 SERIES 2000 PROGRAMMABLE COMMERCIAL THERMOSTATS AND SUBBASES
Terminal Designations
Standard
Alternate
EB, EB
G
F
O
R
R
V
RC
RH
T, T
W1
H1, R3
W2
H2, R4, W3, Y Stage 2 heating relay.
W3
X
b
, C, X1, X2 Common.
B
X1, X3
A, A1, A2, C,
L, X, Z
X4
Y1
C1, M, Y
Y1, Y
RS, M
Y2
C2
Y3
BM
FC
GH
GL
P1, P2
RM
C, H, L
O
P
R1, R2
T
a
Some OEM models reverse the economizer terminal designations A1 and A2.
b
Some OEM models label the terminal for transformer common B.
c
Applies only to Q7300H2037.
63-4355—4
Table 6. Terminal Designations and Descriptions. (Continued)
Typical Connection
Q7300H L
W
® bus connection to L
ON
ORKS
Fan relay.
Cooling changeover valve.
24V system transformer.
24V cooling transformer.
24V heating transformer.
Remote sensor input for T7047 or T7147.
Stage 1 heating relay (Q7300A,G,H) or auxiliary heat relay
(Q7300C,D,H).
Stage 3 heating relay.
User defined Light Emitting Diodes (LED).
LED common.
Stage 1 compressor contactor (Q7300C,D,H).
Stage 1 cooling compressor (Q7300A,G,H
Stage 2 cooling compressor (conventional).
Stage 2 compressor contactor (heat pump).
Stage 3 cooling compressor.
ML7984 Actuator connection (Q7300H
valve closed; call for stage 1 heat, valve approximately one-half
open; call for stage 2 heat, valve fully open.
Fan control transformer (Q7300H
High-speed fan output (Q7300H
cooling.
Low-speed fan output (Q7300H
and fan On selection.
Pump interlock relay (Q7300H
hydronic heat or energizes conventional heat system.
ML7984A Actuator connection (Q7300H
valve closed; call for stage 1 heat, valve approximately one-half
open; call for stage 2 heat, valve fully open.
HSII Control Panel.
Momentary circuit changeover.
Defrost.
Low- and high-speed fan relays.
External temperature readout, T-relay; outdoor thermistor.
W
® network.
ON
ORKS
c
,L).
c
, L only); no call for heat,
c
, L only).
c
, L only); activate during calls for
c
, L only); activated on calls for heat
c
, L only); operates circulator pump in
c
, L only); no call for heat,
8
Terminal
Function
Type
Input, Output Communi-
cations
Output
24V powered
contact
Output
24V powered
contact
Input
Input
Input
Input
Output
24V powered
contact
Output
24V powered
contact
Output
24V powered
contact
Input
Annunciation —
Annunciation —
Output
24V powered
contact
Output
24V powered
contact
Output
24V powered
contact
Output
24V powered
contact
Output
Input
Output
24V powered
contact
Output
24V powered
contact
Input, Output 24V powered
contact
Output