Modification Of E, F Page Data - Sony DCR-PC2E Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC2E:
Table of Contents

Advertisement

Address
Remark
6B
Fixed data-1
6C
(Initialized data)
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80 to FF
Table. 5-1-4.
1-2-4.
INITIALIZATION OF E, F PAGE DATA
1. Initializing the E, F Page Data
Note: If the E, F page data has been initialized, following adjustments
need to be performed again.

1) Modification of E, F page data

2) Camera system adjustments
3) Video system adjustments
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 01, and set data: 2D (NTSC) or data:
2F (PAL) , and press the PAUSE button of the adjustment remote
commander.
3) Select page: 6, address: 03, set data: 01, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 6, address: 02, and check that the data is "01".
5) Perform "Modification of F, E Page Data".
2. Modification of E, F Page Data
If the E, F page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
[Modification of "Fixed data-2" address data]
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note : If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
[Modification of page: F, address: 1B data]
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 0A, and check the data.
• When the data is "70" to "90"
Select page: F, address: 1B, set data: 0D , and press the
PAUSE button
• When the data is "00" to "20"
Select page: F, address: 1B, set data: 01 , and press the
PAUSE button
Processing after Completing Modification of E, F Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
5-14
F
10 to FF
E
00 to 47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc3eDcr-pc3

Table of Contents