Initialization Of B, C, D, E, F Page Data; Initialization Of C Page Data; Modification Of C Page Data - Sony DCR-PC2E Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC2E:
Table of Contents

Advertisement

1-2.

INITIALIZATION OF B, C, D, E, F PAGE DATA

1-2-1.

INITIALIZATION OF C PAGE DATA

1. Initializing the C Page Data
Note: If the C page data has been initialized, the following adjustments
need to be performed again.

1) Modification of C page data

2) Servo and RF system adjustments
3) Video system adjustments
Adjusting page
C
Adjusting Address
10 to DF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 80, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 80, and check that the data changes to
"1C".
4) Perform "Modification of C Page Data".
2. Modification of C Page Data
If the C page data has been initialized, change the data of the "Fixed
data-2" address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note : If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. C Page Table
Note: Fixed data-1 : Initialized data. (Refer to "1. Initializing the C Page
Data".)
Fixed data-2 : Modified data. (Refer to "2. Modification of C Page
Data".)
Initial value
Address
NTSC PAL
00 to 0F
10
EE
EE
11
00
00
12
EE
EE
13
00
00
14
15
16
E0
E0
17
E0
E0
18
2A
2A
19
2A
2A
1A
1B
33
33
1C
33
33
1D
1E
25
25
1F
3E
3E
20
3E
3E
21
DC
DC
22
99
99
23
24
25
88
88
26
E3
E3
27
A1
A1
28
29
2A
2B
04
04
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
00
00
39
00
00
3A
00
00
3B
00
00
3C
00
00
3D
00
00
3E
00
00
3F
00
00
40
00
00
5-8
Remark
Switching position adj.
Fixed data-1
(Initialized data)
Cap FG duty adj.
Treel FG duty adj.
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL f
adj.
0
APC adj.
LPF f
adj.
0
Fixed data-1
(Initialized data)
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
(Initialized data)
Chroma BPF f
adj.
0
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Emergency memory address