(2) Operation panel removal
(I) Remove the panel cover.
- Insert a thin flat-blade screwdriver in a gap between the panel cover and FAU top cover, then gently lift
the panel cover up to remove it.
- Slide the panel forward by pushing up its backside with a screwdriver to release the four claws under the hinge.
- For the claws locations, see the photo in the left which shows the back side of the panel.
(indicated by the red circles)
- For the hole locations on the panel, see the photo in the right.
(The green circles shows the holes which are usually covered by the LCD monitor.)
(II) Remove the panel board.
- Remove three screws.
- Detach the panel board from the FAU top cover. Take notice that the panel board is hung on the right / left ditch.