Function Test&Alignment Procedure; Test Equipment Needed; Service Mode; Factory Reset - Optoma PK-102 Serivce Manual

Hide thumbs Also See for PK-102:
Table of Contents

Advertisement

Chapter 4
Function Test&Alignment Procedure

4-1 Test Equipment Needed

- DVD player with Multi-system (NTSC/PAL)
- Equipped "Component", "S-Video" , "Composite"
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- Remote control (P/N: 45.89Z01G001 only for PK-102 test using)
- PK-102 universal to VGA cable (P/N: 42.00206G001-B)
- Mini JACK-M to 3*RCA-F R/W/Y cable (P/N: 42.00235G001-B)
- PK-102 universal to USB cable (P/N: 42.00288G001-B)

4-2 Service Mode

1. Turn on the projector
2. Do the following actions sequentially to get into service mode
- Press "VGA" button on remote control
- Service mode will be shown
- After confirm the configutation, press "Menu" to exit

4-3 Factory Reset

1. The following actions will allow you to erase all end-users' settings
and restore the default setting:
(1) Press ''VGA'' button on remote control to get into service mode.
(2) Press ''Select''->''Down''->''Down''->''Down''->''Select''
button of the remote control to execute Freset function.
(Such as:
->
->
->
->
)
PK-102
Select
Down
Confidential
4-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents