T8600D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS
Keys to
Test
Press
Number
41
40
Key Operation System Test
Time ∆
60 1
NOTE: Press any key and the displayed numbers change. Press Time ∇ to go to the previous test and Time ∆ to go to
the next test. The Run Program key does not exit this test. Press Time ∆ or Time ∇ and then the Run Program
key to exit.

THERMOSTAT INFORMATION

1. Press the Time ∆ key to access the thermostat
information.
2. Press the increase
date code. The first two large digits are the month
and the third digit is the last digit of the year
(Example: 027 = February 1997)
.
3. Press the increase
ware identification code. (Example: 02 = software
ID code 2).
69-1409—1
Table 5. Installer System Test Options. (Continued)
Fan comes on.
Fan turns off.
Change from fan to key operation system test.
M14613
key to display the production
M14614
key again to display the soft-
M14615
Description
4. Press the increase
ware revision number (Example: 001 = Revision
number 1).
5. Press the increase
EEPROM identification code. (Example: 314 =
EEPROM ID 314).
6. Press the Run Program key to exit the system test.
The system test times out after four minutes with-
out any key presses.
CHECKOUT
Outdoor Temperature Sensor
(Select Models)
Allow the outdoor temperature sensor to absorb the
outdoor air for a minimum of five minutes before taking a
reading.
10
key again to display the soft-
M14617
key again to display the
M14617