Download Print this page

Honeywell Switches and Sensors Brochure page 25

Honeywell industrial switches and sensors brochure

Advertisement

24CE/924CE Series
Miniature Safety
Electromechanical
Switches
Actuators
For position sensing and switching applications requiring direct acting, positive opening contacts the
24CE and 924CE ranges are ideal. They have been tested and approved to meet the requirements of the Low
Voltage directive and positive opening safety contacts per IEC/EN 60947-5-1-3. The devices are CE marked.
The red colour clearly differentiates this safety component in the application. The 924CE range also has UL
and CSA approval.
It is possible for the end user to enhance the safety level of these switches from Category 1 on their own to
Categories 2, 3 or 4 when the switches are used in conjunction with our wide range of FF-SR safety relays to
form a safety system.
Typical applications for these switches would use the roller plunger 24CE2- or 24CE3- style in conjunction
with cams on doors with hinges; or our fixed side rotary 24CE16- style for detection of sliding doors. Also
available are a range of panel mounting or top mounting versions to ensure that small space or difficult
mounting can be simply achieved.
Several contact arrangements are available.
Mechanical life:
Sealing:
Operating temperature:
Approvals:
Connection:
Contacts:
Switching options:
924CE
black
red
green
Slow action contacts (1NC/1NO), Break Before Make (BBM)
black
red
green
Zb
white
white
Slow action contacts (1NC/1NO), Make Before Break (MBB)
black
red
green
Zb
white
white
Electrical ratings:
Designation & Utilization
Category
AC15
DC13
Free position
1NC: 8,4 /
1NC/1NO: 9,5 /
www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
standard type: IP66; with boot seal type: IP67
24CE
Low temperature: -40 °C (-40 °F)
924CE
0 °C to 105 °C (32 °F to 221 °F)
24CE
924CE
per UL file #E41859, 10 A 250 Vac; 1/3 Hp 125-250 Vac
Harmonised CENELEC 3 or 5 x 0,75 mm
SJTO 3 or 5 x 18 AWG cable (924CE)
Slow action contacts (1NC)
blue
blue
Zb
black
blue
Zb
black
IEC 60947-5-1/EN 60947-5-1
Rated operational current le (A)
at rated operational voltage Ue
120 V
240 V
380 V
480 V
B300
3
1.5
-
-
125 V
250 V
R300
0,22
0,1
40 /
max.
1.58
16 /
max.
0.63
25 /
0.98
2 Holes 5,1 dia
Counter Bored 10,2 dia x 6 deep
(both sides - option 'A' only)
49 /
max.
1.93
8 /
0.32
Side exit cable
(Option 'A')
.33
.374
Note: connector versions also available
10 million
0 °C to 70 °C (32 °F to 158 °F)
CE
AC15 B300
DC13 R300
CSA, CE
AC15 B300
DC13 R300
2
cable (24CE)
Silver
24CE
brown
green/yellow
brown
green/yellow
black
brown
green/yellow
black
VA
rating
500 V
600 V
Make
Break
-
-
3600
360
28
28
23

Advertisement