Annex; Electrical Properties - Fujitsu Siemens Computers D1562 Technical Manual

Answers2
Table of Contents

Advertisement

Annex

Electrical Properties

Loadability for connections and fuses
i
Make sure that the connected devices do not overload the connections.
Valid for Mainboard variant A
Fuse no.
-
1
750 mA
2
1500 mA
3
1500 mA
4
1500 mA
5
1500 mA
Valid for Mainboard variant C
Fuse no.
-
1
1500 mA
2
1500 mA
3
2000 mA
The fuses on this mainboard can be used several times (polyfuses). Shortly after the error state has
been eliminated, the fuses reset to the original state.
A26361-D1562-Z121-1-6319
Fuse
-
Fuse
-
Connection
Fan1, Fan2
Keyboard
Mouse
VGA port
USB port A
USB port B
USB port C
USB port D
USB port E
USB port F
USB port G
USB port H
Connection
Fan1, Fan2
Keyboard
Mouse
VGA port
USB port A
USB port B
USB port C
USB port D
USB port E
USB port F
USB port G
USB port H
Maximum loadability
1000 mA each
Not specified
Not specified
Minimum 50 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
Maximum loadability
1000 mA each
Not specified
Not specified
Minimum 50 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA