Electrical adjustments
[BIAS adjustment]
Conditions : VOLUME
: MIN
Input signal
: No signal (no load)
Procedure : Adjust RV4101 on the BIAS board so that 10mV is
obtained across the CN4103, CN4153, CN4203,
CN4303 and CN4353 on the AMP board respectively.