Tradeline
models are selected and packaged to provide ease of stocking,
ease of handling,
and maximum
re-
placement
value. Tradeline
model specifications
are the same as those of standard models except as noted below.
L4017B
Combination
Fan
and
Limit
Control.
TRADELINE
MODELS AVAILABLE:
MANUAL-AUTO
fan switch and 10 inch [254
L4017B
Combination
Fan
and
Limit
Control.
mm]
self-supporting
element.
Includes
limit
MANUAL-AUTO
fan switch,
60 inch [I524
stop adjusting tool.
mm]
capillary
sensing element.
Includes limit
ADDITIONAL
FEATURES:
Tradeline
pack
with
stop adjusting tool and element support bracket.
cross reference label and special instruction
sheet.
STANDARD
MODELS
MODELS:
L4017A
Combination
Fan and Limit Control.
Unit
has adjustable fan-on and high limit set points with
fixed limit and adjustable
fan differentials.
With
case and cover.
L4017B
Combination
Fan and Limit Control.
Unit
has adjustable
fan-on
and high limit set points
with fixed limit and adjustable
fan differentials-
with MANUAL-AUTO
fan switch. With case and
cover.
ELECTRICAL
RATING (amperes):
I
FAN
I
LIMIT
DIA.
HOLE
IN MTG SJR-
FACE
FOR
DIRECT
IN-
120v
240V
12QV
24QV
AC
AC
AC
AC
Full Load
14
7
8
4
Locked Rat&.
84
42
48
24
0.25
amp at 0.25 to 12V dc (limit only).
Maximum connected
load- 2000 VA.
MAXIMUM AMBIENT TEMPERATURE:
190 F [ 88 C]
at switches and 300 F [ 149 C] at sensing element.
LIMIT DIFFERENTIAL:
Fixed at 25 F [ 14 C].
SWITCH
ACTION:
Fan
switch
makes
at set point
(adjustable differential
model) and limit switch breaks
at set point on temperature
rise. Fan switch breaks at
set point on model with fixed differential
on tempera-
ture fall.
FIG. I-L4017A
AND
B DIMENSIONS,
IN INCHES
[MILLIMETERS
IN BRACKETS],
AND
LO-
CATjON
OF MOUNTING
HOLES.
(continued
on page 3)
WHOLESALER
OR YOUR DISTRIBUTOR,
REFER TO THE TRADELINE
CATALOG
OR PRICE SHEETS FOR
COMPLETE ORDERING
NUMBER.
SPECIFY-
4. OPTIONAL
SPECIFICATION,
IF DESIRED.
1. MODEL NUMBER,
TRADELINE
IF DESIRED.
5. FAHRENHEIT
OR CELSIUS SCALEPLATE
2. SELF-SUPPORTING
ELEMENT OR CAPILLARY.
AND RANGES, IF DESIRED.
3. CAPILLARY
LENGTH
(CAPILLARY
MODELS ONLY).
6. ACCESSORY,
IF DESIRED.
IF YOU HAVE ADDITIONAL QUESTIONS, NEED FURTHER INFORMATION, OR WOULD LIKE TO COMMENT ON OUR
PRODUCTS OR SERVICES, PLEASE WRITE OR PHONE:
I. YOUR LOCAL HONEYWELL RESIDENTIAL DIVISION SALES OFFICE (CHECK WHITE PAGES 0~ PHONE DlR~cT0Ryb
2. RESIDENTIAL DIVISION CUSTOMER SERVICE
HONEYWELL INC., 1885 DOUGLAS DRIVE NORTH
MINNEAPOLIS, MINNESOTA 55422 (612) 542-7500
(IN CANADA-HONEYWELL
CONTROLS LIMITED, 740 ELLESMERE ROAD, SCARBOROUGH, ONTARIO MIP 2VB)
INTERNATIONAL SALES AND SERVICE OFFICES IN ALL PRINCIPAL CITIES OF THE WORLD.