Rear Panel - Yamaha EXi8 Owner's Manual

Input/output expander
Table of Contents

Advertisement

Controls and Connectors

Rear Panel

i
q
w
NOTE
The EXi8/EXo8 has some connectors that are shaped identically
but have a completely different function (e.g., NETWORK connec-
tor, [YDIF] connector). Make the appropriate connections as
instructed by the explanation for each connector. Otherwise, you
risk damaging your equipment.
q Ground screw
The supplied power cord has a three-prong plug that will
ground the device when plugged into an appropriately
grounded three-prong type AC mains outlet. In some cases,
you may be able to reduce hum or interference by also con-
necting this screw to ground.
w AC IN connector
Use the included power cord to supply power to this connec-
tor. First, connect the power cord to this device, and then
insert the power cord plug into the AC outlet.
e [UNIT ID] rotary switch
This switch specifies the ID by which EXi8/EXo8 units are
individually distinguished in the MTX system network. You
must specify the ID avoiding duplicates among the MTX
series, XMV series and the EXi8/EXo8 within the same net-
work.
DIP switches 1 and 2 described in r specify the upper digit,
and this rotary switch specifies the lower digit, together
allowing you to set the UNIT ID to one of 63 possibilities in
the range of 01 to 3F.
NOTE
• Do not use a UNIT ID of "00" (DIP switches 1 and 2
upward and the rotary switch at 0).
• You'll need to restart the device after changing the setting
of the [UNIT ID] rotary switch.
8
EXi8/EXo8 Owner's Manual
e r
t
y
u
r DIP switches
These switches enable you to specify the settings related to
the startup operation of the EXi8/EXo8.
NOTE
Set the DIP switches while the power to the unit is turned
OFF. Otherwise, the setting will not be effective.
Refer to the following for details.
Switch
Represent a status with switch toggled up.
Represent a status with switch toggled
down.
Switches 1–2 (UNIT ID)
These switches specify the upper digit and the above-
mentioned [UNIT ID] rotary switch specifies the lower
digit, together allowing you to specify one of 63 different
UNIT ID numbers in a range from 01 to 3F.
Switch position
Option
UNIT ID is
"0x"
UNIT ID is
"1x"
UNIT ID is
"2x"
UNIT ID is
"3x"
NOTE
Do not use a UNIT ID of "00" (DIP switches 1 and 2
upward and the rotary switch at 0).
Switch 3
This switch is for future expansion. Set this to its upward
position.
Switches 4–5 (REMOTE)
Settings of these switches are not necessary. Set these to
their upward position.
Switch position
Option
NATIVE
* Illustration shows EXi8.
Status
Functions
The [UNIT ID] rotary switch
will have a setting range of
01 through 0F.
The [UNIT ID] rotary switch
will have a setting range of
10 through 1F.
The [UNIT ID] rotary switch
will have a setting range of
20 through 2F.
The [UNIT ID] rotary switch
will have a setting range of
30 through 3F.
Function
Enables remote control with
the supported devices.