Panasonic CS-MKS12NKU Submittal Data

Panasonic CS-MKS12NKU Submittal Data

Split system multi system indoor units - wall mounted
Hide thumbs Also See for CS-MKS12NKU:

Advertisement

Split System Submittal Data
Indoor: CS-MKS12NKU
Multi System Indoor Units - Wall Mounted
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:

General Data

Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
Running Amps (A)
Power Input (W)

Indoor Unit

Fan type
Dia & Length (in.) - No. Speeds
No. Speeds
No. Poles (RPM, High)
No. Motors (W)
CFM (HI)
Operation Sound (HI/Med/Lo/
QT*dB-A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in)
Drain Connection Size
Refrigerant
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Discharge)
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Weight (lbs.)
Net
Shipping
Shipping Volume (cu.ft.)
208 - 230/1/60
15
20
0.15
35
Cross Flow
D3-11/16 L24-31/32 -1
3 & Auto
8 - 1200
1-(47)
282
36/33/29/25
Aluminum Plate Fin & Copper
Tube
Slit Plate - Inner Rifled
2 - 19.5
2.02
9/32
23/32
R410A
1/4" (Flare)
3/8" (Flare)
13-25/32 x 35-7/16 x 10-1/32
11-7/32 x 32-15/32 x 7-7/16
Indoor
19.8
24.3
2.82
Approval:
Date:
Construction:
Unit#:
Drawing#:

Performance Data @ ARI Standard Conditions (230V)

Cooling
Total Capacity (BTU/H)
Moisture Removal (HI, Pint/H)

Features

Controls
Remote Control
Temperature Control
Timer
Night Setback
Air Louver, Horizontal
Air Louver, Vertical
Power Failure Automatic Restart
Heating/Cooling Automatic
Changeover
Self-Diagnosis
Quiet Operation
Air Filter
Ion Generator
Air Clean Apatite Filer

Option

Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removeable Remo-con
Bracket

Operating Range

Indoor Air Intake Temp
Cooling (Max)
95F DB/71F WB
Cooling (Min)
67F DB/57F WB
11900
4.26
Microprocessor
LCD Wireless Type, Built-in Temp
Sensor
IC Thermostat
24 Hr. Program, 1 Hr. Off
Built-In
Manual
Automatic
Built-In
Built-In
Built-In
Washable, Anti-Mold
N/A
N/A
Available
N/A
N/A
N/A
Available
Available
Outdoor Air Intake Temp
115F DB
14F DB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS-MKS12NKU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Panasonic CS-MKS12NKU

  • Page 1 Split System Submittal Data Indoor: CS-MKS12NKU Multi System Indoor Units - Wall Mounted Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit#: Submitted by: Drawing#: Reference: General Data Power (V/P/Hz) 208 - 230/1/60 Circuit Ampacity (A) Fuse Size, Max.(A) Running Amps (A) 0.15...
  • Page 2: Indoor Dimensions

    Indoor Dimensions Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon...

Table of Contents