NETGEAR EN516 Installation Manual page 10

Ethernet hub
Hide thumbs Also See for EN516:
Table of Contents

Advertisement

Connect to a Network Using the BNC Port
The BNC port on the rear panel of the hub is used for connecting to a thin coaxial segment. You
can connect other Model EN516 or Model EN524 hubs, servers, workstations, or other devices to
the BNC port. A BNC-T connector is inserted in the port, and the 50
connection at each end device. By using the BNC port for cascading, you treat each connected hub
as just another node on the coaxial segment.
The separation marks in the coaxial cable between the hubs in this illustration represent the
incorporation of other devices and show that interconnection is not limited to hubs.
BNC 50
terminator
Note: Ethernet specifications limit a BNC segment to 30 BNC connections, specify a
minimum of 1.64 feet (0.5 m) between any two stations, and limit segments to 607 feet
(185 m) in length.