Appliance does not operate:
Is the output indicator
light ON?
YES
I s t h e o v e r l o a d
indicator light ON?
Check the electrical ap-
pliance or equipment for
any defects.
No electricity at the DC receptacle:
Is the DC circuit protector
on?
52
NO
YES
NO DEFECTS
DEFECTS
NO
Take the generator to an
authorized Honda generator
dealer.
Take the generator to an
authorized Honda generator
dealer.
Replace the electrical ap-
pliance or equipment.
Take the electrical ap-
pliance or equipment to an
electrical shop for repair.
Stop and restart the engine.
NO
Turn the DC circuit protector
on.
YES
Take the generator to an
authorized Honda generator
dealer.