INSTALLATION INSTRUCTIONS
Installation of Filtration Unit
Determine the best location for the installation of the undersink filtration unit.
Ensure that the hose connections will reach from the water supply to the water
inlet on the filter unit, and the hose connection from the water outlet of the filter
unit up to the connection under the faucet. Make sure water supply is turned
off before proceeding.
CAUTION: Risk of property damage. Do not install unit where the
temperature may drop below freezing.
Installation Overview
Install T-fitting
The T-fitting (packaged in the T-fitting & Stop Valve hardware pack (3)) is used to
divert the cold water supply to the filtration unit. Install the T-fitting into the
cold water line as shown.
1. Attach the T-fitting with washer to the rigid leg of your faucet or stop valve.
Hold the supply leg of the faucet steady by putting a wrench or pliers on the
flats of the supply leg fitting when tightening the T-fitting.
Note: The T-fitting can be installed at either end of the cold water supply line
depending on your line configuration and ease of installation.