Sensor Resistance Characteristic Tabie - LG GR-B197WVS Service Manual

Sxs refrigerator
Hide thumbs Also See for GR-B197WVS:
Table of Contents

Advertisement

MICOM CIRCUIT DESCRIPTION
2. Sensor Resistance Characteristic Table
Measured Temperature (°C)
-20 °C
-15 °C
-15 °C
-5 °C
0 °C
+5 °C
+10 °C
+15 °C
+20 °C
+25 °C
+30 °C
+40 °C
+50 °C
• Tolerance of sensor resistance is ±5 %.
• Leave the sensor at measuring temperature for more than 3 minutes when measuring sensor resistance.
(necessary due to detecting speed)
• It is desirable to use digital tester as analogue tester has wider measuring temperature.
• Disassemble refrigerator sensor 1 and 2 from CON8 of main PWB assembly and measure it with digital tester.
• Disassemble freezer sensor from CON7 of main PWB assembly and measure it with digital tester.
Freezer Sensor
22.3 k
16.9 k
13.0 k
10.1 k
7.8 k
6.2 k
4.9 k
3.9 k
3.1 k
2.5 k
2.0 k
1.4 k
0.8 k
- 49 -
Refrigerator Sensor 1 and 2, Defrost Sensor and
Open Air Sensor
77 k
60 k
47.3 k
38.4 k
30 k
24.1 k
19.5 k
15.9 k
13 k
11 k
8.9 k
6.2 k
4.3 k

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents