Resistance Specification Of Sensor; Exploded View And Replacement List - LG LTCS20220W Service Manual

Hide thumbs Also See for LTCS20220W:
Table of Contents

Advertisement

8-3 RESISTANCE SPECIFICATION OF SENSOR

TEMPERATURE
-20 °C (-4 °F)
-15 °C (5 °F)
-10 °C (14 °F)
-5 °C (23 °F)
0 °C (32 °F)
5 °C (41 °F)
10 °C (50 °F)
15 °C (59 °F)
20 °C (68 °F)
25 °C (77 °F)
30 °C (86 °F)
40 °C (104 °F)
50 °C (122 °F)
The resistance of the SENSOR has a ±5% common difference.
Temperature of the SENSOR must be stabilized for minimum of 3 minutes before accurate measurement can be taken
To measure the outputs of the fans on the control boards check the voltages between the pins for the following components:
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB AS
FAN
Freezer Fan
Cooling Fan
PIN
1
N/C
RESISTANCE OF REFRIGERATOR &
DEFROST SENSOR
PIN NUMBER PIN NUMBER
Con 4 pin 5
Con 4 pin 6
Con 4 pin 2
Con 4 pin 3
CONNECTOR 4
2
3
4
C-FAN
G
V
F
77
60
47.3
38.4
30
24.1
19.5
15.9
13
11
8.9
6.2
4.3
OUTPUT VOLTAGE
MOTOR ON MOTOR OFF
10 - 14 VCD 2 VCD or less
10 - 14 VCD 2 VCD or less
5
6
7
F-FAN
G
V
N/C
- 30 -
VOLTAGE
3.73
3.49
3.22
2.95
2.67
2.4
2.14
1.89
1.66
1.46
1.27
0.96
0.72
8
9
10
N/C
N/C
N/C
N/C

Hide quick links: