MICOM FUNCTION

1. Monitor Panel
1-1. GR-P247, GR-P207, GR-L247, GR-L207, GR-L197
MAX
MIN
FRZ
REF
TEMP
TEMP
Freezer compartment
Refrigerator compartment
temperature control Button
temperature control Button
2. Description of Function
2-1. Funnction of Temperature Selection
Division
Power Initially On
MAX
Change of
MIN
Indication Lamp
FRZ
TEMP
Temperature
Medium
Control
Freezer
-19 °C
Control
(-18 °C)
<-19 °C>
Refrigeration
3 °C
Control
<2 °C>
* The temperature can vary ±3 °C depending on the load condition.
1. When power is initially applied or reapplied after power cut, "Medium" is automatically selected.
2. When the temperature selection switch in the freezer and refrigerator compartments is pressed, the light is on in the
following sequence:
"Medium"
"Medium Max"
3. The temperature setting condition of freezer and refrigerator compartments shall not be indicate in the standard model
(GR-P247, GR-P207, GR-L247, GR-L207, GR-L197, GR-C247, GR-C207, GR-B247, GR-B207) when refrigerator or
home bar door is closed.
Function display board
CRUSH WATER
CUBE
SELECT
Dispenser selection button
1st Press
MAX
MIN
REF
FRZ
REF
TEMP
TEMP
TEMP
Medium Max
-22 °C
(-20.5 °C)
<-20.5 °C>
1.5 °C
<1 °C>
"Max"
"Min"
"Medium Min"
1-2. GR-C247, GR-C207, GR-B247, GR-B207, GR-B197
Max
5
4
3
2
1
FRZ
Temp
2nd Press
MAX
MIN
FRZ
REF
FRZ
TEMP
TEMP
TEMP
Max
-23 °C
(-22 °C)
<-22 °C>
<-16.5 °C>
0°C
<0 °C>
*(
) : 127V/60Hz, 110~115V/60Hz, 115V/60Hz Rating ONLY.
*< > : TAIBEI
"Medium"
- 32 -
Min
1
2
3
4
5
Max
REF
Temp
3th Press
4th Press
MAX
MAX
MIN
MIN
REF
FRZ
TEMP
TEMP
Min
Medium Min
-15 °C
-17 °C
<-18 °C>
6 °C
4.5 °C
(7 °C)
<4.5 °C>
<3 °C>