Dell PowerEdge C8000 Hardware Owner's Manual page 264

Servers
Hide thumbs Also See for PowerEdge C8000:
Table of Contents

Advertisement

<command> is the command for configuring the fresh air mode
For example, the command line should have the following format:
ipmitool –I lanplus –P root -U root –H 192.168.70.58 raw 0x30 0x43 0x01
0x01
2 You can do either of the following commands to view the server enclosure
fresh air status:
To view the server enclosure fresh air status when the fresh air mode is
enabled, enter the following command:
ipmitool –I lanplus –P root -U root –H 192.168.70.58 raw 0x30 0x44
0x1 01
To view the server enclosure fresh air status when the fresh air mode is
disabled, enter the following command:
ipmitool –I lanplus –P root -U root –H 192.168.70.58 raw 0x30 0x44
0x01 00