Table 2-15. MRC Fatal Error Code
POST Code Nomenclature
ERR_MEM_TEST_MINOR_
SOFTWARE .
ERR_MEM_TEST_MINOR_HARDTW
ARE
ERR_MEM_TEST_MINOR_LOCKSTE
P_MODE
ERR_VENDOR_SPECIFIC
ERR_DIMM_COMPAT
ERR_MIXED_MEM_TYPE
ERR_INVALID_POP
ERR_INVALID_POP_MINOR_QR_AN
D_3RD_SLOT
ERR_INVALID_POP_MINOR_UDIMM
_AND_3RD_SLOT
ERR_INVALID_POP_MINOR_UNSUPP
ORTED_VOLTAGE
84
Using the System Setup Program
(continued)
Major
Code
0ECh
0EDh
Code
Description
Minor
01h
Software memtest
failure
02h
Hardware memtest
failed
Hardware Memtest
03h
failure in Lockstep
Channel mode requiring
a channel to be disabled.
This is a fatal error
which requires a reset
and calling MRC with a
difffernt RAS mode to
retry.
UDIMMs and RDIMMs
are both present DIMM
vendor-specific errors
Different dimm types
01h
are detected installed in
the system
Violation of population
02h
rules
The 3rd DIMM slot can
03h
not be populated when
QR DIMMs are installed
UDIMMs and
04h
SODIMMs are not
supported in the third
DIMM slot
05h
Unsupported DIMM
Voltage