DXE Phase
Table 2-8. DXE Phase
Status Code
0x60
0x61
0x62
0x63
0x64
0x65
0x66
0x67
0x68
0x69
0x6A
0x6B
0x6C
0x6D
0x6E
0x6F
0x70
0x71
0x72
74
Using the System Setup Program
Description
DXE Core is started
NVRAM initialization
Installation of the South Bridge Runtime Services
CPU DXE initialization is started
CPU DXE initialization (CPU module specific)
CPU DXE initialization (CPU module specific)
CPU DXE initialization (CPU module specific)
CPU DXE initialization (CPU module specific)
PCI host bridge initialization
North Bridge DXE initialization is started
North Bridge DXE SMM initialization is started
North Bridge DXE initialization (North Bridge module
specific)
North Bridge DXE initialization (North Bridge module
specific)
North Bridge DXE initialization (North Bridge module
specific)
North Bridge DXE initialization (North Bridge module
specific)
North Bridge DXE initialization (North Bridge module
specific)
South Bridge DXE initialization is started
South Bridge DXE SMM initialization is started
South Bridge devices initialization