Dell PowerEdge C5230 Hardware Owner's Manual page 63

Servers
Hide thumbs Also See for PowerEdge C5230:
Table of Contents

Advertisement

Boot Event
The BIOS downloads the system date and time to the BMC during POST
and logs a boot event. Software that parses the event log should not treat the
boot event as an error.
Table 2-1. POST Error Events
Byte
Field
1:2
Record ID
3
Record Type
4:7
Time Stamp
8:9
Generator ID
10
EvM Rev
11
Sensor Type
12
Sensor Number
13
Event Dir | Event
Type
14
Event Data 1
15
Event Data 2
16
Event Data 3
Value
XXXXh
02h
XXXXXXXXh
0100h
04h
0Fh
DAh
00h
A0h
XXh
XXh
Using the System Setup Program
Description
ID Used for SEL Record access
02h = system event record
Time when event was logged
Generate by BIOS
Event Message Format Revision.
04h for this specification
Sensor type code for sensor that
generated the event
Number of Sensor that generated
the event
Bit 7 0 = Assert Event
Bit 6:0 Event Type Code
Bit 7:6 10b = LSB POST error
code in byte 2
Bit 5:4 10b = MSB POST error
code in byte 3
Bit 3:0 Offset from Event/Reading
Code for discrete
event status
POST error code, LSB
POST error code, LSB
63

Advertisement

Table of Contents
loading

Table of Contents