SAFETY PRECAUTIONS

A. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer.
B. Before servicing or cleaning unit, switch
power off at service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
C. Do not use this unit with any solid-state speed
control device.
A. SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
B.
You may be burned.
C. DO NOT USE WATER, including wet dishcloths
or towels–a violent steam explosion will result.
*Based on "Kitchen Firesafety Tips" published by
NFPA.
READ ALL INSTRUCTIONS BEFORE USING
WARNING
This unit must be grounded.
.
WARNING
Use an extinguisher ONLY if:
1. You know you have a Class ABC
extinguisher, and you already know how to
operate it.
2. The fire is small and contained in the area
where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an
exit.

READ AND SAVE THESE INSTRUCTIONS.

IMPORTANT SAFETY INSTRUCTIONS

WARNING
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
B. Always turn hood ON when cooking at high
heat or when flambéing food (ie: Crepes
Suzette, Cherries Jubilee, Peppercorn Beef
Flambé).
C. Clean ventilating fans frequently. Grease
should not be allowed to accumulate on fan
or filter.
Use proper pan size. Always use cookware
appropriate for the size of the surface
element.
WARNING
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to
prevent back drafting. Follow the heating
safety standards such as those published
by the National Fire Protection Association
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities. When
applicable, install any makeup (replacement)
air system in accordance with local building
code requirements. Visit GEAppliances.com
for available makeup air solutions.
C. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
Ducted fans must always be vented to the
outdoors.
WARNING
Do not attempt to repair or replace any
part of your hood unless it is specifically
recommended in this manual. All other
servicing should be referred to a qualified
technician.