OPERATION
PUMP PREPARATION
Suction Hose Connection
Use a commercially
available hose, hose connector, and hose
clamps. Hose must be the same size or larger than the suction port.
To prevent hose from collapsing,
use a hose that is reinforced with a
noncollapsible
wall or braided wire construction.
Keep pump as close
as possible to the pumping liquid. Avoid hose bends and sharp turns.
Pump performance
is best when the pump is not far above the liquid
level and the hose is kept straight. Self-priming time is also
proportional
to the suction hose length. Using a longer suction hose
will increase the self-priming
time.
Tighten the hose connector to the suction hose with a hose clamp to
prevent air leakage and loss of suction. Verify that the connector
sealing washer is installed and in good condition. A loosely
connected
suction hose will reduce pump performance
and
self-priming
ability.
SEALING
WASHER
\
SUCTION
HoSE \
DISCHARGE
cc_,,-,
FE
COUPLING
\
STRAINER~~
The strainer provided with the pump should be attached to the end of
the suction hose as shown.
Always install the strainer on the end of the suction hose before
pumping. The strainer will prevent debris from entering the pump that
can cause clogging, diaphragm and/or other pump damage.