Electrolux EN18WI30LS Service Manual page 22

Gas water heater
Hide thumbs Also See for EN18WI30LS:
Table of Contents

Advertisement

<EN19WI30LS, EP19WI30LS>
Circuit Board Checkpoints
Ref.
Part
No.
Overheat Prevention
1
Device (Thermal Fuse)
Heat Exchanger Flow
2
Control Valve
Bypass Flow
3
Control Valve
4
Water Flow Sensor
Water Inlet
5
Thermistor
Water Outlet
6
Thermistor
Heat Exchanger
7
Thermistor
8
Exhaust Thermistor
9
Flame Rod
10
Fan Motor
11
Fan Motor
12
Igniter
Primary Gas
13
Solenoid Valve
14
Gas Solenoid Valve - 1
15
Gas Solenoid Valve - 2
16
Gas Proportioning Valve
17
Flame Rod
18
Gas Solenoid Valve - 3
19
Gas Solenoid Valve - 4
20
High Limit Switch
21
Air Inlet Thermistor
22
Water Level Electrode
Power Supply
-
(Power Circuit Board)
Power Supply
-
(Main Circuit Board)
-
Remote Controller
Note 1) Inlet / Outlet / Heat Exchanger Thermistor Temperature Characteristics
Temperature (° F)
Temperature (° C)
Resistance (k )
Note 2) Exhaust Thermistor Temperature Characteristics
Temperature (° F)
Temperature (° C)
Resistance (k )
Voltage (V)
Note 3) Air Inlet Thermistor Temperature Characteristics
Temperature (° F)
Temperature (° C)
Resistance (k )
Circuit board Check points
CN & Pin No.
Wire color
CN10
3
W - BK
23
W - O
23
W - G
CN38
23
W - V
23
W - BK
6
Y - BL
23
W - O
23
W - G
CN38
23
W - V
23
W - BK
10
Y - BL
3
R - BL
CN38
5
Y - BL
CN63
4
W - W
CN63
1
W - W
CN63
3
W - W
CN63
7
W - W
BL -
1
Burnercase
CN78
BL -
1
Electrode
CN27
4
BR - BL
1
R - BL
CN27
3
Y - BL
CN197
1
BK - BL
CN10
5
W - BL
CN10
9
BK - BL
CN10
8
GY - BL
CN101
7
R - BL
BL -
1
Burnercase
CN78
BL -
1
Electrode
CN10
10
O - BL
CN10
7
BR - BL
CN10
3
W - W
CN63
5
W - W
CN38
31
W - BL
CN92
1
W - BK
C102
4
R - BL
CN89
1
BL - BL
32
50
68
86
0
10
20
30
23.7
15.5
10.3
7.0
-4
14
32
50
-20
-10
0
10
487
296
162
98.3
4.6
4.3
3.9
3.4
-4
14
32
50
-20
-10
0
10
106.5
59.6
34.4
20.6
Normal value
CN & Pin No.
1
CN10
2
or less
16
DC 1 - 16 V
18
DC 1 - 16 V
20
CN38
DC 1 - 16 V
24
DC 1 - 16 V
17
DC 1V or less
25
DC 1 - 16 V
26
DC 1 - 16 V
27
CN38
DC 1 - 16 V
28
DC 1 - 16 V
17
DC 1V or less
17
DC 14 - 16 V
DC 0.5 - 15 V
CN38
17
over 408 pulses/min.
(over 6.8Hz)
2
CN63
DC 1 - 4.5 V
2
CN63
DC 1 - 4.5 V
2
CN63
DC 1 - 4.5 V
2
CN63
Note 2)
GND
-
10 kHz - 100 kHz
Flame
-
DC 0.45 A or less
Rod
2
CN27
DC 7 - 45 V
2
DC 10 - 14 V
CN27
2
100 Hz - 400 Hz
3
CN102
DC 14 - 16 V
DC 14 - 16 V
6
CN10
19 - 31
DC 14 - 16 V
6
CN10
36 - 58
DC 14 - 16 V
6
CN10
36 - 58
DC 0.3 - 15 V
6
CN101
50 - 80
GND
-
10 kHz - 100 kHz
Flame
-
DC 1 A or more
Rod
DC 14 - 16 V
6
CN10
36 - 58
DC 14 - 16 V
6
CN10
36 - 58
12
CN10
1
or less
2
CN63
DC 0.7 - 4.4 V
17
CN38
DC 14 - 16 V
3
CN92
AC 108 - 132 V
3
C102
DC 14 - 16 V
3
CN89
DC 14 - 16 V
104
122
140
158
40
50
60
70
4.9
3.5
2.5
1.9
68
86
Note 4)
The ON/OFF condition of water level electrode
20
30
can be checked using the maintenance
61.4
39.5
monitors.
When maintenance monitor number 19 reads
2.8
2.3
"000", the condition of the electrode is normal.
When this monitor reads "001", the condition of
68
86
the electrode is abnormal.
20
30
12.6
8.0
22
Remarks
When valve is fully open
When valve is fully open
Y (+)
BL (-)
32 - 212° F
0 - 100° C Note 1)
32 - 212° F
0 - 100° C Note 1)
32 - 212° F
0 - 100° C Note 1)
When no flame is detected
4 pulse/revolution
When igniter is sparking
When valve is open
Coil resistance
When valve is open
Coil resistance
When valve is open
Coil resistance
Coil resistance
At flame detection
When valve is open
Coil resistance
When valve is open
Coil resistance
Contact resistance
176
80
1.4
Note 2)
Note 3)
Note 4)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep18wi30lsEn19wi30lsEp19wi30ls

Table of Contents