SELF-DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.
IF ... IS DISPLAYED
LOW TEMPERATURE
(frost prevention)
PROBE FAILURE
(sensor damaged)
FULL TANK

SETTING THE TIMER

The timer can be used to delay appliance start up or shutdown. This avoids wasting electricity by
not operating the appliance when it is not needed.
How to program delayed start up
• Plug the appliance into an outlet and press the ON/STAND-BY button (A), then select the desi-
red operating mode and other settings (temperature, fan speed, etc).
• Press the ON/STAND-BY button (A) again: The appliance switches to stand-by mode (the two
central segments are displayed).
• Press the TIMER button (D). The last timer setting or the preset value 6.0 flashes on the display.
• Use the + (E) or - (F) buttons to set the number of hours delay before the appliance comes on.
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected. If the + (E) or - (F) buttons are pressed for more than 2
seconds, the time runs rapidly up to a maximum of 24 hours. Press the timer button again within
a few seconds to confirm the setting. If the setting is not confirmed within a few seconds, the
display resets to Stand-by. With the timer activated, the countdown before the programmed
start up time is displayed and the light (H) flashes.
To cancel the timer programming, press the timer button (D) again.
How to program delayed shutdown
• Delayed shutdown can be programmed in any operating mode (air conditioning/dehumi-
difying/fan).
• Press the TIMER button (D). The last timer setting or the preset value 6.0 flashes on the display.
• Use the + (E) or - (F) button to set the number of hours delay before the appliance goes off.
During the first ten hours, you can select half hour intervals. For times greater than ten hours,
one hour intervals can be selected.
If the + (E) or - (F) buttons are pressed for more than 2 seconds, the time runs rapidly up to a
maximum of 24 hours.
Press the timer button again within a few seconds to confirm the setting.
When the timer is set, the light (H) flashes.
At the set time, the air conditioner shuts down and remains in stand-by.
To cancel the timer programming, press the timer button (D) again.
Self-diagnosis
The appliance is fitted with a frost protection device to avoid
excessive formation of ice on internal components. The appliance
starts up again automatically when the defrosting process is com-
pleted
If this is displayed, contact your local authorized service centre.