Bullard RT Series User Manual

Bullard RT Series User Manual

Rt series respirator hood

Advertisement

Quick Links

Bullard RT Series Respiratory Systems provide a continuous flow of air from
a remote air source via airline. The flow of air is delivered to the respirator
wearer through a patented air delivery system. RT Series respirators
offer protection from airborne contaminants that are not immediately
dangerous to life or health (IDLH), or that do not exceed concentrations
allowed by applicable OSHA, MSHA, EPA, NIOSH or ACGIH regulations and
recommendations, or any other applicable regulations for continuous flow
airline or powered air-purifying respirators.
RT Series airline respirators are approved by NIOSH (TC-19C-412
Type C). Bullard has determined that these respirators may be used to
provide respiratory protection in general purpose applications, including
pharmaceutical manufacturing, chemical and pesticide handling, tank
cleaning, spray painting and other industrial or agricultural applications in
which hazardous compounds are present.
Bullard RT hoods are available in two different Tychem
hoods will accommodate limited facial hair without compromising the level of
protection. The hood is held in place by the inflatable neck cuff (RT1 and RT2)
or a sport material neck cuff (RT3 and RT4), which fits under the wearer's
chin and provides a positive seal. This keeps the hood in position on the
head and prevents it from rising upwards when supplied with breathing air.
Breathing air is supplied from a breathing tube connected to the back of the
hood, and the air is routed through overhead channels that deliver the air
down across the lens of the hood.
RT Series respirators are compatible with breathing air sources such as
breathing air compressors. Bullard offers the appropriate approved breathing
tube, flow control device and air supply hose to connect the RT Series
respirator to these breathing air sources.
RT Series respirators are approved by NIOSH for use with optional Bullard
climate control devices. Contact Bullard or our local authorized distributor
for more information about these and other accessories for RT Series
Read all instructions and warnings before using these respirators. Save this manual for future reference.
The RT Series respirator's air source must supply clean, breathable air, Grade D or better, at all times. The RT respirator does not purify air or filter out
contaminants. Connecting the RT respirator to a line supplying nitrogen or other harmful gases could cause death or serious injury. Failure to follow these
instructions could result in death or serious injury.

Table of Contents

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Breathing Air Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Breathing Air Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Breathing Air Supply Hoses and Hose Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Breathing Air Pressure Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Respirator Assembly
Installing Breathing Tube Assembly in Respirator Hood . . . . . . . . . . . . . . . . . . 6
Using Climate Control Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
materials. Bullard
®
. . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
RT Series Respirator Hood
respirators. All Bullard parts must be present and properly assembled to
constitute a NIOSH approved respirator. For technical assistance, contact
Bullard Cutomer Service at 877-BULLARD (285-5273) or 859-234-6616.
NOTE
Bullard RT Series hoods are also NIOSH approved for certain PAPR
configurations. Please refer to your Bullard PAPR manual or call
Customer Service at 877-BULLARD (285-5273).
WARNING
Donning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Removing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Hood. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Breathing Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Flow Control Valve/Climate Control Device. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Air Supply Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
User Manual
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Advertisement

Table of Contents
loading

Summary of Contents for Bullard RT Series

  • Page 1: Table Of Contents

    Read all instructions and warnings before using these respirators. Save this manual for future reference. The RT Series respirator’s air source must supply clean, breathable air, Grade D or better, at all times. The RT respirator does not purify air or filter out contaminants.
  • Page 2: Approval Label

    LIMITATIONS2 CAUTIONS/ DC70XLXXL DC70ML ACCESSORIES 36501 V20100ST V2050ST 54511 54510 5454 5457 46917FM 46917FF 46917 46916FF 46916FS 46915 46913 4696 V5KF2530XXX V5KF2531XXX V5KF2532XXX V5KF2533XXX V5KF2535XXX V5KF5030XXX V5KF5031XXX V5KF5032XXX V5KF5033XXX V5KF5035XXX V5KF2533XXXFF V5KF2533XXXFS V5KF5033XXXFF V5KF5033XXXFS V55033FS V55033GRN V52533FF V52533FS V52533 V55030GRN V55031 V55030 V55032...
  • Page 3: Component Concept - Rt Series Hood

    See parts list (page 11) (page 11) for details. Series respirator in use. list (page 11) for for details. 8. Never alter or modify this respirator. Use only NIOSH approved Bullard RT Series details. components and replacement parts for this respirator. www.bullard.com...
  • Page 4: Operations

    Locate the source of supplied air, whether it is a breathing air compressor Protection or an ambient air pump, such as a Bullard Free-Air® pump, in a clean air Respiratory environment. Locate the air source far enough from your work site to ensure The RT Series respirator is NIOSH approved (TC-19C-412) as a Type C the air remains contaminant-free.
  • Page 5: Breathing Air Pressure Table

    RT Series Respirator Hood User Manual for use with supplied air respirators Special or Critical User’s Instructions RT Breathing Air Pressure Table This table defines the air pressure ranges necessary to provide CC20 Series respirators with a volume of air that falls within the required range of 6-15 cfm or 170-425 lpm according to U.S. Government regulations (42 CFR, Part 84, Subpart J, 84.150, Table 8).
  • Page 6: Installing Breathing Tube Assembly In Respirator Hood

    To do this, first determine how much shorter you need to make the tube. The foam from inside the breathing tube, used with RT Series Airline Respirators. tube cannot be shortened more than 6 inches. Mark a line with a marker pen The foam helps reduce the noise level of incoming air.
  • Page 7: Donning

    Breathable Air Source Air Supply Hose 4. With air still flowing, put on RT Series respirator hood. Pull the hood over your head until the neck cuff is securely around your neck. NOTE The RT3 and RT4 hoods have an adjustable velcro strap near the top of the lens that allows the user to customize the curvature of the lens to his/her personal preference.
  • Page 8: Respirator Use

    Failure to heed these instructions may result in minor or Bullard RT Series respirators have a limited service life. Therefore, a regular moderate injury and/or equipment damage.
  • Page 9: Breathing Tube

    WARNING tion, distortion and damage from elements such as dust, direct sunlight, heat, Do not cut or remove the foam that is inside the RT Series Airline extreme cold, excessive moisture and harmful chemicals. Five-year maximum Respirator breathing tube. The foam helps reduce the noise level of shelf life.
  • Page 10: Parts And Accessories

    Parts and Accessories RT Series airline respirators consist of four components – respirator hood, breathing tube, flow control device, and air supply hose. All components must be present and properly assembled to constitute a complete NIOSH approved respirator. CATALOG CATALOG...
  • Page 11 Hose-to-pipe, 3/8” hose to 3/8” pipe V5KF5030XXX 50’ (15.2 m) with 1/4” Industrial Interchange steel Other Available Flow Control Assemblies (without breathing (Hansen compatible) fittings tube) for RT Series Airline Respirators V5KF2531XXX 25’ (7.6 m) with 1/4” Schrader steel quick- Adjustable Flow disconnect fittings 1/4”...
  • Page 12: Return Authorizations

    2. Verify with your Customer Service specialist that the product should be returned to Bullard. Customer Service will provide you with written permission and a return authorization number as well as the labels you will need to return the product.

Table of Contents