6. 3D Test
Procedure
Inspection item
Inspection Distance - < 6M
Criteria

4-9 ADC Calibration

1. Video Calibration
Calibration
Procedure
Check pattern
Inspection item
Criteria
EX540/EX542/EX612/EX615/EX762/EX540I/EX542I/ES523ST/EW533ST
- Test equipment: DVD Player
- Test signal: 1280X720@120Hz (HQFS format CD)
- 3D test
- The image should not appear noise, flicker,
- Test equipment: video generator
- Once Main Board is changed, video calibration
should be done as well.
(1) Test signal: 480i
(2) Test Pattern: SMPTE BAR
- Note
(1) Calibration pattern should be in full screen mode.
(2) Please refer to 4-2 Guide to get into service
mode 1 and choose "ADC calibration".
(3) Choose and get into "Video Calibration", press
"Enter" button to execute "Video Calibration". When
the message "Success" appears, it means "Video
Calibration" is OK. Choose "Menu" or "Exit" to
leave service mode 1.
- Test signal: 576p, 720p, 1080i
- Test pattern: Master
* After finishing Video adjustment, check Master
pattern.
- Color saturation
- There should not have any lack of SMPTE BAR.
- The screen appears normal, it shouldn't appear
any abnormal condition, such as lines and so on.
- It is unacceptable that the color appears
abnormal and flashing.
SMPTE BAR
Master