Over-Current Of The Compressor - Haier 2U14CS1ERA Service Manual

Ek series wall mounted type dc inverter
Hide thumbs Also See for 2U14CS1ERA:
Table of Contents

Advertisement

2U14CS1ERA-SM
Service diagnosis

7.4.6 Over-current of the compressor

Outdoor Display
LED1 flash 3 or 24 or 25 times
Method of
The current of the compressor is too high
Malfunction
Detection
Malfunction
when the IPM Module is damaged
Decision
or the compressor is damaged
Conditions
power supply. voltage is too low or too high
Supposed
Faulty IPM Module
Causes
Faulty compressor
Faulty power supply
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or
parts damage may be occurred.
59