Gigabit Ethernet Indicators
The Gigabit Network Port card has the following indicator lights:
Label
ACT/LNK
Green flashing
(Left)
10=OFF
100=GREEN
1000=YELLOW
(Right)
Access To Components
Be certain to shut down the server and disconnect the power cord before
opening the unit for service.
The following sections provide instruction on disassembly and re-assembly for maintenance.
Opening the Front Panel
The front panel is easily opened for access to the twelve disk drives, or for removing the server
from an equipment rack. Using a coin or a flat-blade screwdriver, unscrew the two large panel
fasteners on the left and right sides of the face panel. Pull outward and down to remove cover.
To re-install the front panel, verify that all wires are within the chassis, then place the front
panel into position and tighten the front panel access screws just enough to be snug.
Removing the Top Cover
Remove 3 Phillips screws from the rear edge and 2 from the middle of the top panel, slide the
cover toward the rear of the chassis, then lift.
(On older model servers, there may be latch buttons on the top panel. Press down on the two
latch buttons simultaneously, slide the cover toward the rear of the chassis, then lift.)
MAXX-2400HD Owner's Manual
Indication
Green on
The port is connected to a valid link partner
Off
Off
Green
Yellow
Meaning
Data activity
No link
10 Mb/sec
100 Mb/sec
1000 Mb/sec