Programming GPIO Outputs
The MAXX-2400HD has twelve General Purpose Outputs, referred to as GPO 1 through 12. Each
can be programmed to go active on the selected channel when one of the following events occurs:
IDLE
PAUSED
STOPPED
PLAYING
RECORDING
RAID System Fault
NO GENLOCK
NO VIDEO INPUT
PLAYLIST
To program a GPO output, select EDIT->CONFIGURE->GPO. The screen of Figure 16 is
displayed. GPO 1 through 12 are triggerable outputs. The checkboxes to the right of each selection
represent channel 1, 2, 3 and 4. GPO 9 is shown with the trigger option pulldown expanded.
1. To activate one of the GPO, pulldown the event menu and select which event will activate
the GPO.
2. Select an associated channel where applicable by checking the channel checkbox.
3. Click APPLY to activate.
Page 52
Transport returns to idle
Transport is paused
Transport is stopped
Transport is playing
Transport is recording
RAID or System Fault
No genlock
No video at the selected input
Control GPO via playlist
Figure 16 - GPO Configuration Screen
MAXX-2400HD Owner's Manual