Aiphone IS SERIES Setting Manual page 7

Commercial & security ip video intercom system; standard (ip) system
Hide thumbs Also See for IS SERIES:
Table of Contents

Advertisement

Title
Sub title
System setting Advanced station
settings
Zone setting
Item
Master station
Stations to be scan monitored
Central
control unit
Room sub
control unit/
Add-on
control unit
Zone number
-
Stations
-
PA output
-
Sub item
(Select up to 20 sub stations from the
registered ones.)
Master station function:
ON/OFF
paging, chime, monitor,
door release, and
remote site call
(Contact input)
S1 to S4
Contact type
Normally open (NO)
/Normally closed (NC)
Trigger condition
None/Broadcast chime/Stop chime
Sound source
Internal sound source (Select a
(Only when "Broadcast
sound fi le or sequence name from
chime" is selected at
the registered ones in the list.)
"Trigger condition")
/External sound source (Select either
External sound source 1 or 2.)
Chime priority
Normal/Priority/Urgent
(Only when "Broadcast
chime" is selected for
"Trigger condition")
Zone name
(Select from the registered ones.)
(Only when "Broadcast
chime" is selected at
"Trigger condition")
(Contact output
L1 to L8
terminal)
Contact type
Normally open (NO)
/Normally closed (NC)
Trigger condition
None/Calling notice/Door release
/External sound source/PA output
Calling notice
Normal: OFF/ON
(Only when "Calling
Priority: OFF/ON
notice" is selected at
Urgent: OFF/ON
"Trigger condition")
Door release
(Select from the sub stations
(Only when "Door
registered and set for the central
release" is selected at
control unit.)
"Trigger condition")
External sound source
External sound source 1
(Only when "External
/External sound source 2
sound source" is
selected at "Trigger
condition")
PA output
PA output 1 to 4
(Only when "PA output"
is selected at "Trigger
condition")
(Contact output
L1 to L4
terminal)
Contact type
Normally open (NO)/Normally closed
(NC)
Trigger condition
None/Calling notice/Door release/PA
output
Calling notice
Normal: OFF/ON
(Only when "Calling
Priority: OFF/ON
notice" is selected at
Urgent: OFF/ON
"Trigger condition")
Door release
(Select from the sub stations
(Only when "Door
registered and set for each control
release" is selected at
unit.)
"Trigger condition")
PA output
PA output 1 to 4
(Only when "PA output"
is selected at "Trigger
condition")
(Select from the registered ones.)
(Select from the list.)
(Select from the list.)
Setting range
-
ON
S1
Normally open
(NO)
None
-
Normal
-
L1
Normally open
(NO)
None
Normal: OFF
Priority: OFF
Urgent: OFF
-
-
-
L1
Normally open
(NO)
None
Normal: OFF
Priority: OFF
Urgent: OFF
-
-
-
-
-
Default
7

Advertisement

Table of Contents
loading

This manual is also suitable for: