Screws, M2.5×4 mm
(1 on OB 6100 models,
2 on some OB 6000 models)
Screw, M2.5×17mm (OB 6100)
Screw, M2.5 x 6mm (OB 6000)
Screws, M2.5×8mm (2)
(OB 6100)
Screws, M2.5×6mm (2)
(OB 6000)
Reassembly Notes
Before installing any screws, make sure the center hinge cover fits over the tab in the bottom case.
Important
Make sure the DIP switches on the display interface PCA match the settings shown on the
label on the display cable, or you risk damaging the display.
Omnibook 6100: Reprogram the BIOS IC, preferably with the latest BIOS for display
compatibility.
Omnibook 6000: If you change the DIP switches, use the service utilities disk to reprogram
the EEPROM—see page 2-31. If the EEPROM is not programmed correctly, the display will
not turn on.
2-14
Removal and Replacement
Screw, M2.5×5mm
Label with DIP
switch settings
Figure 2-10. Removing the Display
Screws,
M2.5×6mm (5)
HP Omnibook 6000/6100