In this mode minimum and maximum speed is automatically calibrated. Calibration lasts less
than 3 minutes; belt will be in motion during this test.
***Caution*** : Do not stand on the running belt while performing these test.
WHEN SHOULD AUTO-CALIBRATION BE ENGAGED?
Auto-calibration should be done every time MN, MX SPD & UNITS parameters have been
changed in either MANAGER or MAINTENANCE MODES. Auto-calibration must be
engaged when speed controlling components have been upgraded or replaced such as;
MCB, Display Board, Drive Motor & RPM Sensor.
1.
Press and hold the " 0 ", " 2 " & " START " keys together (or the "0" , "2" ). While holding
the " 0 " & " START " keys down, release the " 2 " key. The display will beep and
display MAINTENANCE MODE.
2.
Press and release the "8" key. Display will read: 240 3 .0 if treadmill is at 0%.
3.
Press
speed calibration for less than 3 minutes. Press "STOP" key to exit Motor Test.
NOTE: If Auto-calibration fails to give the correct response refer to Chapter 4.
4.
Press
Speed Calibration
key, display will read: CALI treadmill will go into an automatic
key to exit Motor Test.
19